SDJ-09 Bench Mounted Static Eliminator




Sensitive parts require a highly efficient static eliminator that can reduce static electricity to almost 0V. If proper maintenance is not done, however, the ion balance is disrupted, causing reverse charging and air pollution.

Because the SDJ-09 adopts a capacity coupling method using eight discharging needles, it can generate stable ionic air with an ion balance of ±5V. With the help of a 100 hour timer that displays and informs the need for cleaning the needle electrode, the SDJ-09 can establish control standards for needle maintenance.

Features

  • Highly reliable piezoelectric AC transformer
  • Because the innovative disk-type discharge plate adopts a capacity coupling mehtod, it can prevent the disruption of ion balance and is ideal for the removal of static electricity from sensitive electronic devices
  • Easy cleaning and replacement of the discharge plate
  • Equipped with a warning alarm that indicates troubles such as high-pressure and fan failure or fan failure
  • Unique 100 hour timer signals workers with a flashing lamp, indication necessary discharge needle cleaning


Static Electricity Removal for:
  • Electronic device manufacture and assembly workstations
    (DVD or CD manufacturing equipment, optical devices, watches, semiconductors, LCD, precision parts, etc.)
  • Processing and filling of food containers
  • Film lamination and peeling of LCD panels
  • Prevention of adhesive stringing in gluing processes
  • Molded parts on conveyors (injection/vacuum/blow molding)
  • Dust adherence prior to printing or coating
  • Stockers, winders and Thompson punching and cutting processes for paper. film, sheet
  • Oscillating parts loaded into parts feeders


Ion Generation Method
High-Voltage DC Corona Discharge
Input Voltage
DC 24V ±5%
Output Voltage
AC 3.5kV
Working Temp. Range /
Working Humidity Range
0~50° C / 35~65% RH
Dimensions
9.4" x 7.3" x 4.0" (L x W x H)
240mm x 185mm x 102mm (L x W x H)
Weight
4.2lb (1.9Kg)
Ion Balance
0V ± 5V (measured at 11.8" (300mm) in front of unit at max air flow
Ozone Generation
< 0.019ppm (1.5L/min, measured at 1.97" (50mm) in front of unit at max air flow



SDJ-09 Stat-Buster Elimination Range Chart


SDJ-09 Stat-Buster Dimensions

SDJ-09 Spec Sheet

alt


Required to view Product Flyer