Description
- High voltage 4kV power supply with two power outputs
- Adjustable output voltage (AC)
- Adjustable ion balance circuit
- Safety/anomaly detection circuit
- Output monitoring port
- Easy to see pilot lamp
The GP-1 is a high voltage power supply and should be used with its dedicated AC adapter #AD24-GP. The GP-1 power supply unit is intended to be used with different VESSEL model ionizers to address various production problems caused by electrostatic charges. It’s equipped with two output terminals for operating two applicable ionizers at the same time.
Applicable models: HPG-1, HPN-1, HPF-1, SJ/SL-Series, HPB-Series
Features
- AC output voltage adjustment function
It can adjust AC output voltage within the range of 3.5 kV to 7 kV in order to power VESSEL ionizer models: HPG-1, HPN-1, HPF-1, SJ-Series, HPB-Series
- DC output voltage adjustment function
It can output a variable DC output voltage between -150 VDC and +550 VDC on top of the AC output voltage so you can adjust the ion balance if needed.
- Safety / anomaly detection circuit
It incorporates a safety circuit that will automatically shut off the output when a high-voltage or short circuit is detected.
- Visible bright blue power indicator light
You can easily see if the power is on or off from far away. The power indicator light goes out when an anomaly is detected.
- High voltage output confirmation function
- The GP-1 must be used with #AD24-GP AC power supply adapter (sold separately).
Specifications
Model Number (EDP #) |
GP-1 (623044) |
Power Supply Input |
AC corona discharge / 3.5kV / 50/60Hz (adjusted on GP-1 4kV) |
Rated Input Voltage |
24V DC ±10% |
Ion Balance |
Adjustable on GP-1 4kV (charged plate monitor or equivalent is required) |
Variable Output Range Without Loud (rms) |
AC Output 4kV DC output -150V to +550V |
Secondary Short Circuit Current |
5mA or lower |
Output Monitor |
1/100V ±5% of the output voltage is to emit to the monitor terminals |
Low-Voltage Detection |
Anomaly detection function will operate when each output drops to about 85% or less of the set voltage due to high voltage short circuit or abnormal sparks |
Overcurrent Detection |
Anomaly detection function will operate when the output current is about 4mA or more |
Anomaly Detection Sensitivity Adjustment |
The anomaly detection response speed can be adjusted using external adjustment knob |
Dimensions (LxHxD) |
4.1" x 4.5" x 9.2" (102.8 x 114.2 x 233.5mm) |
Estimated Weight |
9.9 lbs (4.5kgs) |
Termination Connector |
CON-4 high-pressure connector |
Power Supply Input |
Molex 5569-04A1-210 |
Air Supply Hose Diameter |
Ø8mm Tube Fitting, One-touch joint |
Noise Level |
95dBA (43.5psi / 0.3MPa) |
Working Temp Range |
32-122°F (0 - 50°C) |
Working Humidity Range |
10~90% RH (non-condensing, non-freezing) |
Operating / Warning Indicators |
GP-1 4kV high-voltage power supply provides high-voltage anomaly detection function and automatic stop circuit |
Materials |
Housing: SPCC, painted white |
High-Voltage Connector |
Ceramic high voltage output terminal x2 |
Alarm Output Terminal |
C contact relay output |
Includes
|
High-Voltage Cable (3m), User's Manual |
Markings |
CE, RoHS |
Country of Origin |
Japan |
Dimensions